TAC Vista®, TAC Menta®, TAC Xenta® and TAC I-talk® are registered trademarks of TAC AB. TAC Xenta 280 - 300 - 401 Handbook.
![Tac Menta Tac Menta](http://www.techbri.com/en/images/201202/goods_img/1296_G_1329413739151.jpg)
The question is not on the topic, but we are specialists in a wide range. To control the input and output in both directions, readers are placed, not buttons. Cases: accounting of working hours, control of movement, increased security and simply customer's wants. The distance from the reader to the controller is determined by the documentation on the reader. More than 50m did not meet. If you do not fit - it is usually treated by installing the power supply unit from the reader. These are general principles, regardless of the controller.
Maybe you did not ask about it, but about the remote button at the guard sitting far from the door? The distance in this case is not important, provided that the resistance of the cable lies within the threshold limits of the controller's operation. This is at least hundreds of meters. TAC does not do its ACS. Vista integrates with INet. Is your controller from there, or am I out of life?
The post has been edited by ganz72 on 2.7.2012, 22:36. In the attached file - TAC Vista V. Total 3 CD-ROM.
Demo license for TAC Vista IV - Disk 1. Demo license for TAC Vista V - drive 3. Demo COMPLETELY functional, just 'expiration date is limited'. For V, if I'm not mistaken, I'll have to 'twist the time.' Licenses are ordinary text files, so you can look at 'Notepad'. Files are available until 2009-10-31!!!!
And can, please, if it is not difficult for a particularly gifted instruction to brief how to use these disks. I downloaded a bunch of archives. I so understood that archives of type CD1.part1.CD1.part7 need to be extracted in one file.
And I do not know what to do next. Installed them CD3 / TAC Vista 5.0.2 TACMenta502 / Firstly, when installing some errors were, and secondly, I could not attach a license to it. I took the license in CD3 / License Explain please what I'm doing wrong. And another question, where else can I get the software for TAC, the same TACMenta at least DEMO??? There is a specific question. In Vista 4, visualization is being twisted. Everything works, the evidence changes.
If you open Folders, you can find a list of controllers over the Lonworks network. So one of them is marked with an asterisk. When you hover over it, you get a 'need to be commissioned' prompt. Well, I try to start up. I press the right mouse button on the controller and in Properties select 'Commissioning and download'. The TAC VISTA Load window pops up. There is a button with green up and down arrows.
It seems that the initialization is over, the connection is established and eventually writes: 'Waiting for device to resrart'. After 8 seconds: 'resuming operation' After 30 seconds everything repeats: Waiting and resuming. Pinhole zhmakal on the controller - did not help.
What he wants from the documentation that was the location and the Help button - this sitauutsiya is not described. Who will tell me what?
Simulation mode (simulation) In this mode, the display is divided into 2 windows, one with a diagram (Diagram window) the other with registration of parameter changes (Trend window). The first window shows the FBD itself or a table of all common signals and parameters. In the simulation mode, the work program can be executed continuously, step by step (one cycle) or a specified number of cycles. During the simulation you can monitor the signal values. The second window (Trend window) allows to simulate the behavior of physical inputs, change signals and record changes.